Partition Instalation

  1. The length of screws for fixing gypsum board to metal stud is equal to the thickness of gypsum board plus 10 mm
  2. The thickness of the metal stud should be 0.45 mm
  3. The vertical metal stud should be set int the same direction
  4. If the width of the partition is above 15 m at every 15 m interval an expansion joint must be used in order to prevent cracking
  5. Always lift the gypsum board 10 mm above the floor
  6. In high humidity area, especially in the kitchen or bathroom, U-line stud which is laid on the floor should be wrapped with plastic sheet before installation. The moisture resistant gypsum board is most suitable for this purpose